1-31Setting and Operating Outline1External interfaceTerminal blockItem SpecificationsParallel interface Input: 8 points, Output: 9 points, 12/24 VDCGeneral-purpose serialinterface RS232C/RS422 (2.4 to 115.2 kbps)Computer link Built-in compatibility with certain SHARP, OMRON, Mitsubishi andYokogawa modelsUSB USB device node (Compatible with USB1.1)Image output 1 channel, Equivalent to NTSC system, 2:1 interlaceNumber of cameras Maximum of 2Connecting camera IV-C30C5, IV-S30C3, IV-S30C4Make settings Using the IV-S30RK1 remote keypad and/or the IV-S30SP parametersetting support softwareMeasurementstart inputInternal trigger Color CCD trigger, (Gray) CCD triggerExternal trigger Trigger input (parallel I/F), general-purpose serial I/F, keypad trigger (formanual measuring)Inputs Number of points 8 points: External trigger; 1 point (X0), Object type change; 5 points (X1 toX5), external input; 2 points (X6, X7)Common terminal 1 point: + or - commonOutputs Number of points 9 points: 1 READY , 8 user settable logical outputs (Y0 to Y7)Common terminal 1 point: + or - commonPowersupplyPower supplyterminal 2 points: +24 VDC, 0 VPower supply voltage 24 VDC (±10%)Power consumption 12 WStorage ambient temperature -20 to 70o COperation ambient temperature 0 to 45o COperation ambient humidity 35 to 85% RH (non-condensing)Operation atmosphere No corrosive gases or dustVibration resistance JIS C 0911 or equivalentShock resistance JIS C 0912 or equivalentNoise immunity 1000 Vp-p 1ms width impulse (by noise simulator) when applied to theprimary side (100 VAC) of an external DC power supplyOutside dimensions 130 (W) · 100 (D) · 42 (H) mm (except protruding portions)Weight Approx. 600 g