SAMSUNG MMC PROGRAMSCOMBINED SYSTEMS PROGRAMMING MANUAL FEBRUARY 2004MMC 211 (Page 1 of 2)MMC: 211 DOOR RING ASSIGNMENTFOR: ALL SYSTEMSPurpose: Designates which devices will ring when a door phone button is pressed. Op-tions can be selected for ring plans (1–6) on iDCS and OS500 systems, or for day andnight mode on other systems. Two types of device can ring: a station or a station group.Q For all systems except iDCS & OS500ACTION DISPLAY1. Open programming and select 211Display shows first door phone [201] DOOR RINGD:500 N:500(If there is no door phone interface module, yousee “DOOR NOT EXIST”)2. Dial doorphone number (e.g., 210)ORPress VOLUME keys to scroll through door phonenumbers and use the RIGHT soft key to movecursorORSelect all stations (see section 1.5.2)[210] DOOR RINGD:500 N:5003. Enter day selection (e.g. 301)ORPress VOLUME keys to make selection andpress RIGHT soft key[210] DOOR RINGD:301 N:5004. Enter night selection (e.g. 302)ORPress VOLUME keys to make selection andpress RIGHT soft key[210] DOOR RINGD:301 N:3025. Press RIGHT soft key to return to step 2ORPress LEFT soft key to return to step 3ORPress Transfer/TRSF to store and exitORPress SPEAKER to store and advance to nextMMCDefault Data: Station group 500 for day and night (group 50 for 408/408i sys-tems)Related Items: None