SAMSUNG MMC PROGRAMSCOMBINED SYSTEMS PROGRAMMING MANUAL FEBRUARY 2004MMC 508 (Page 1 of 1)MMC: 508 CALL COSTFOR: ALL SYSTEMSPurpose: Sets the Call Cost attributes generated by the system during a call. This in-formation can be displayed on the keyphone LCD during a call or as an SMDR record.Attributes are as follows:0 UNIT COST PER MPWhen the system is configured to receive MP on a C.O. outgoing call, this is used forgenerating total call cost by multiplying it by the number of pulses. Allows a maximumvalue of 5000. The value is displayed as ECENT (Euro cents) or PENCE depending onwhether the ‘USE EURO’ option in MMC 210 is set on or off.1 CALL COST RATE (%)This generates additional call cost calculated by multiplying this rate by the original callcost. Ranges from 100 to 250.WARNING• Changing a value when there is a call in progress may result in an inaccurate callcost.• This MPD facility requires the Meter Pulse Detection version of the trunk card. It isnot available on the standard product.ACTION DISPLAY1. Open programming and select 508Display shows UNIT COST PER MP0200 PENCE→2. Dial 0 or 1 (e.g. 1)ORPress VOLUME keys for selection and pressRIGHT soft key to move cursorCALL COST RATE100% →_3. Enter new value (e.g. 110 for 110 percent)System returns to step 2CALL COST RATE110% →4. Press Transfer/TRSF to store and exitORPress SPEAKER to store and advance to nextMMCDefault Data: UNIT COST PER MP=0200 pence / EcentCALL COST RATE=100%Related Items: MMC 110 Station On/OffMMC 210 Customer On/OffMMC 414 MPD/PRS Signal