6. Move the cursor to DWELL TIME, and then tilt thejoystick left or right to select an alarm detect dwelltime setting.After alarm detection, the next alarm is not detecteduntil the specified dwell time elapses.Tilting the joystick cycles through the settingdisplay in the sequence shown below. (unit: sec)7. Move the cursor to RECOVER TIME, and then tiltthe joystick left or right to select an alarm reset timesetting.Tilting the joystick cycles through the settingdisplay in the sequence shown below. (unit: sec,min)If you set OFF, then it does not reset until some otheroperation is done.Notes:• Use the mask setting to mask areas where thereis wind movement of curtains, etc.• Use a lower sensitivity level (LEVEL) setting forareas where illumination is low and prone todigital noise. Also note that operation error canoccur when the illuminance of a subject ischanged suddenly by the headlights of passingcars, turning lights on or off, etc.• There is a delay of about 0.2 second from thepoint that the camera detects change(movement) in the image and the point that asignal is sent to the alarm terminal of a VTR, etc.• Alarms are not output while the setting menu isdisplayed, unless demo mode alarm output isturned on.• Alarms are not output when PAN, TILT, ZOOM,FOCUS or other functions are operating.• When the motion detector is set to MODE 1 orMODE 2, it outputs alarm data during theblanking period. This can cause operationalproblems for a VTR or other device that uses atime code signal, etc. Turn off the motiondetector when not using coaxial communication.• The motion detector is not intended for use asspecialty device for the prevention of theft, fire,etc. The manufacturer assumes no responsibilityfor any accidents that occur or any lossesincurred while this product is being used.(2) Preset Alarm Setting (PRESET ALM)Turning on the preset alarm will output an alarm fromthe video output port or alarm output connector whenthe camera completes a move to a preset position. Analarm is output in the following cases.• When the self return function is activated (page 35)and the camera finishes moving to the homeposition, and when switching to the auto mode.• When SEQ is selected for the auto mode (page 35),and the camera completes a move to a presetposition during sequential movement• When SORT is selected for the auto mode (page35), and the camera completes a move to a presetposition during SORT movement• When AUTO PAN is selected for the auto mode(page 35), and the camera completes a presetmove up to the AUTO PAN start point• When the camera completes a move to a presetposition during manual operation• When PLAY is selected for the PATROL mode(page 37), and the camera completes a presetmove up to the patrol start pointUse the following procedures to configure preset alarmsettings1. Move the cursor to PRESET ALM, and then tilt thejoystick left or right to toggle it on and off.ON : Turns on the preset alarm function.OFF : Turns off the preset alarm function.Note: Turn off the preset alarm function beforedownloading or uploading preset data.(3) Alarm Input/Output (ALARM IN/OUT)Use this setting to specify what operation the camerashould perform when it an alarm signal is input to thealarm input connector or output from the alarm outputconnector.Note: While the camera is in the AF mode or the lensmoves between WIDE and TELE, alarm input may beignored if several alarm inputs are received insuccession.1. Move the cursor to the ALARM IN/OUT O and thenpress the CAM (SET) button.This will display the alarm setting menu.2. Move the cursor to ALARM IN 1, and then tilt thejoystick left and right to select the operation thecamera should perform when an external signal isreceived by ALARM IN 1.OFF : Ignore alarm input signals.1POSI : Move to preset position 1.AUTOPAN : Start auto pan.PATROL1 : Start PATROL 1.PATROL1 (S) : Start PATROL 1, and maintain thestored picture quality settings(page 37) even after completion.AUTOTRACK1 : Move to preset position number 1,and then perform auto tracking.-45-2S ↔ 5S ↔ 10S ↔ 30SOFF ↔ 1MIN ↔ 2MIN ↔ 3MIN ↔ 5MIN ↔ 10MIN60MIN ↔ 30MIN ↔ 20MIN**ALARM IN/OUT**ALARM IN1 OFFALARM IN2 OFFALARM IN3 OFFALARM IN4 OFFCNT-CLS 1 OFFTIME OUT 100MSCNT-CLS 2 OFFCOAX ALM OUT OFFRET TOP