English62Serial ID functionSet to control external control with the PC connected toSERIAL terminal according to the Display’s ID number(Panel ID).[Off]: Disables external control by the ID.[On]: Enables the external control by the ID.LAN control protocolSelect the LAN control protocol.[Protocol 1]: Control with the Panasonic Displaysequence.[Protocol 2]: Control with the sequence thatcompatible with Panasonic Projector.Note● For PJLink and WEB browser control, the operation ispossible regardless of the setting.● When performing the command control with TCP/IP,select [Protocol 1].● When operating the Early warning software or MultiMonitoring & Control Software, select [Protocol 2].Information timingSet up the informing manner for no signal.During RS-232C controls:Warning or error message sent on the displayautomatically.During LAN controls:Acquire the warning or error message from thedisplay.1 Select the item with .Select the set point with .Information timingNo signal warningNo signal warning timingNo signal errorNo signal error timingOn5minOn10min[No signal warning]When set to [On], the display sends out the no signalwarning.[No signal warning timing]Set up the detecting time for no signal warning.(Range: 01 - 60, Interval: 1 minute)[No signal error]When set to [On], the display sends out the no signalerror.[No signal error timing]Set up the detecting time for no signal error.(Range: 01 - 90, Interval: 1 minute)● The warning of [No signal warning] and the error of[No signal error] are not sent when the no signal stateis detected through any of the following functions:[No signal power off], [HDMI1 power management],[HDMI2 power management], [DVI-D powermanagement], [PC power management] (see page51)● If there is no signal when [PC IN] is input, [PC powermanagement] is activated first and the Display entersthe standby mode.Setting Example:[No signal warning timing]: 5 minutes[No signal error timing]: 10 minutes[PC power management]: [On] (60 seconds)Note● The [No signal error timing] cannot be set shorterthan [No signal warning timing].