Chapter 1414-214.2 Error Code Details14.2.1 Error Code Details 0017-6037iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018iT-14-2DisplayCode Detail Code Main Cause/Symptom CountermeasureE000 0000 Startup errorThe temperature detected by the main or sub thermistor doesnot rise to the specified value during startup control.- Check the fixing film connector.- Replace the fixing film unit.- Replace the DC controller PCB.E001 0000 Abnormally high temperature (detected by main thermistor)The main thermistor detected an abnormally high temperature(240 deg C) during temperature control.- Check the connector of the fixing film unit.- Replace the fixing film unit.- Replace the DC controller PCB.0001 Abnormally high temperature (detected by sub thermistor)The sub thermistor detected an abnormally high temperature(295 deg C) during temperature control.- Check the connector of the fixing film unit.- Replace the fixing film unit.- Replace the DC controller PCB.E002 0000 Low temperature during temperature control.The target temperature is not reached during temperaturecontrol.- Check the connector of the fixing film unit.- Replace the fixing film unit.- Replace the DC controller PCB.E003 0000 Abnormally low temperature (detected by main thermistor)After the temperature detected by the main thermistor hasreached the specified value, it does not reach the specified valueduring initial rotation.- Check the connector of the fixing film unit.- Replace the fixing film unit.- Replace the DC controller PCB.0001 Abnormally low temperature (detected by sub thermistor)After the temperature detected by the sub thermistor hasreached the specified value, it does not reach the specified valueduring initial rotation.- Check the connector of the fixing film unit.- Replace the fixing film unit.- Replace the DC controller PCB.E007 0000 Fixing film sensor failureThe fixing film sensor is faulty. - Check the connector of the fixing film sensor.- Replace the fixing film sensor.- Replace the DC controller PCB.E010 0000 Main motor failureThe main motor is faulty. - Check the connector of the main motor.- Replace the main motor.- Replace the DC controller PCB.E019 0000 Waste toner full detectionThe waste toner full state was detected. Replace the drum unit.0001 Waster toner full detection sensor is faulty.The waste toner full state was detected continuously for five ormore seconds while the main motor was turning.- Check the connector of the waster toner full sensor.- Replace the waste toner full sensor.- Replace the DC controller PCB.E052 0000 Erroneous connection to duplex unitDisconnection of the duplex unit was detected after power-on,detection of normal connection to the duplex unit, and start ofcommunication.- Check the connectors of the duplex unit and DC controller PCB.- Replace the duplex controller PCB.- Replace the DC controller PCB.E100 0000 BD detection PCB failureThe BD detection PCB is faulty. - Check the connector of the BD detection PCB.- Replace the laser scanner unit.- Replace the DC controller PCB.E196 0001 Image processor PCB failureError on writing and readout ROM of image processor PCB(mainn ROM).- Putting the switch on/off of the power supply.- Replace the image processor PCB.0002 Image processor PCB failureError on writing and readout ROM of image processor PCB(option ROM).- Putting the switch on/off of the power supply.- Replace the image processor PCB.