* For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-219242Example of fixed 100% output calibration of the FM terminal for reference frequency¾ Adjust Jumper 4 for 0-1 or 4-20 mA output¾ Connect meter to ‘FM’ and ‘CC’.¾ ProgrammingGroup Parameter New ValueUTILITY PARAMETERS Blind Function Selection 1UTILITY PARAMETERS AM/FM Adjustment Parameters Unblind 1AM/FM TERMINAL ADJUSTMENT PARAMETERS FM Terminal Function Selection 14AM/FM TERMINAL ADJUSTMENT PARAMETERS Frequency Meter Adjustment *AM/FM TERMINAL ADJUSTMENT PARAMETERS FM Terminal Function Selection 2* the drive shows ‘100%’. Use the up/down arrows to make meter read the same as the value found in the“Calibration Reading” column on page 2. The drive’s display will not change. Hit ENTER whenadjusted.Example of fixed 100% output calibration of the AM terminal for output current¾ Adjust jumper 4 for 0-1 or 4-20 mA output¾ Connect meter to ‘AM’ and ‘CC’.¾ ProgrammingGroup Parameter New ValueUTILITY PARAMETERS Blind Function Selection 1UTILITY PARAMETERS AM/FM Adjustment Parameters Unblind 1AM/FM TERMINAL ADJUSTMENT PARAMETERS AM Terminal Function Selection 14AM/FM TERMINAL ADJUSTMENT PARAMETERS Current Meter Adjustment **AM/FM TERMINAL ADJUSTMENT PARAMETERS AM Terminal Function Selection 3** adjust until meter reads rated drive amps (or 100% if meter reads percent). Hit ENTER when adjusted.Example of fixed 100% output calibration of the FM terminal for DC bus voltage¾ Adjust jumper 4 for 0-1 or 4-20 mA output¾ Connect meter to ‘FM’ and ‘CC’.¾ ProgrammingGroup Parameter New ValueUTILITY PARAMETERS Blind Function Selection 1UTILITY PARAMETERS AM/FM Adjustment Parameters Unblind 1AM/FM TERMINAL ADJUSTMENT PARAMETERS FM Terminal Function Selection 14AM/FM TERMINAL ADJUSTMENT PARAMETERS Frequency Meter Adjustment ***AM/FM TERMINAL ADJUSTMENT PARAMETERS FM Terminal Function Selection 4