* For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-21922612Adjustable Remote Torque LimitIntroductionThe following programming steps enable on-the-fly remote torque limit on the G3. This limit isadjusted via a speed pot connected to the ‘RR’ terminal. If you want to use another speed pot for aspeed reference, connect its wiper to ‘RX’ and do the required programming (not listed here). Afterthis programming is completed, a new group, GROUP:SUPERUSER, will be visible. Cycle drivepower after programming.ConnectionsTERMINAL STRIPST CCPP RR CCProgrammingGroup Parameter ValueUTILITY PARAMETERS Blind Function Selection 1UTILITY PARAMETERS Feedback Control Parameters Blind 1UTILITY PARAMETERS Protection Function Parameters Blind 1UTILITY PARAMETERS Terminal Selection Parameters Blind 1FUNDAMENTAL PARAMETERS #1 Volts per Hertz Pattern 5FEEDBACK PARAMETERS Drooping Control Enable 1FEEDBACK PARAMETERS Drooping Control Amount 5PROTECTION PARAMETERS Stall Protection Enable 1TERMINAL SELECTION PARAMETERS RR Input Special Function Select 4See Guideline 18, True Torque Control for motor tuning information (necessary for torqueregulation).