INSTALLATION AND CONFIGURATION2-40Document No.: COM-00-05-16 June 2006, Revised June 2014Version: C.12.6.25 Genisys Poll Starting StationThe Genisys poll starting station is used when the serial interface is configured for Genisys ATCSOffice. It designates the starting station number to poll.The default value is 1.To set the Genisys Poll Starting Station:1. On the Second Configuration Menu, select “Genisys Poll Starting Station” to be changed. TheChange Genisys Starting Station Polling Number screen appears.Figure 2-55. Change Genisys Starting Station Polling Number Screen2. To keep the starting station number setting, press ENTER. To change the starting stationnumber setting, enter the new value and then press ENTER. Entry can be any value from 0 to64.The user will be returned to the Second Configuration Menu.3. Prior to exiting the First Configuration Menu, select “Save changes then restart” to savechanges and restart the WAG.2.6.26 Genisys Poll Ending StationThe Genisys poll ending station is used when the serial interface is configured for Genisys ATCSOffice. It designates the ending station number to poll.The default value is 16.To set the Genisys Poll Ending Station:1. On the Second Configuration Menu, select “Genisys Poll Ending Station” to be changed. TheChange Genisys Ending Station Polling Number screen appears.