OfficeServ 7100 SPECIAL APPLICATIONSTECHNICAL MANUAL PART 2 JANUARY 20092.8.14• MMC 615: Program the MGI Use Groups.Set USER=VoIP Networking and choose the IP trunk members (MGI channels)to be used for this “Networking” use. The default values should start withmember 1 = 3801, etc…• MMC 820: Program the following values for LINK ID, SIGNAL G/W (enter theMP10/MP10a IP address for each node), and IP type for each node as follows(SELF refers to the current node you are programming):Index Link ID Signal G/W IP TypeSELF 092 192.168.1.4 PrivateSYS01 091 192.168.1.2 Private• MMC 724: Set up the numbering plans. Trunk group 803 will contain all the IPnetworking trunks.STN NUM PLAN Station numbers (2100 ~ 2399)TRKG NUMBER PLAN 803 (Add other trunk groups here if other trunk cardsare installed. For simplicity, only 803 will be addedhere.)FEAT Dial Number LCR 9 For C.O. outgoing calls, 9+phone numberNTWK LCR NUMPLAN IDX-01:20 converted to 2000~2099 in MMC 824• MMC 210: Tenant On and Off: For LCR ENABLE: Set to ON to enable LeastCost Routing. Set ICM EXT FWD to ON.• MMC 824: Set up the extension dialing plan for the networked system (node A).091 is the node id for Node A. Be sure to set DISP=Y.Index Station Converted SZ Max MB DISP01 20 09120 4 7 N Y Stations in Node A• MMC 714:Entry Digit MOH 1~6 CW Delete Name001 20** - B - 0 -002 21** - B - 0 -003 9 - 9 - 1 -• MMC 310: LCR class of all stations are set to 1 (default) since there is only onepath to the other Node.• MMC 603:803 VoIP networking signaling trunks