OfficeServ 7100 PROGRAMMINGTECHNICAL MANUAL PART 2 APRIL 2007MMC: 852ALMNO.ALMCODE ALARM DEFINITION16 MJC02 Tone FaultAn abnormal interrupt has occurred inthe system tone resources. IE busy,ringback, error, no more calls etc.17-23 NOT USED24 MJC10 AA-DTMF Fault An abnormal fault reported in one of thesystems AA card DTMF resources.25 MJC11 AA-DTMF RecAn abnormal fault reported in one of thesystems AA card DTMF resources hasrecovered.26 MJC12 E911 Restart An E911 card has rebooted27 MJC13 E911 Block An E911 card could not be accessed28-29 NOT USED30 MJC16 WLI Restart The WLI card has restarted31 MJC17 WLI Block The WLI card could not be accessed32 MJD01 Sync Failure Clocking on PRI cards has becomeasynchronous.33 MJD02 Sync Recovery Clocking on PRI cards has becomesynchronous.34 MJD03 Red AlarmLocally detected loss of PCM carrier onPRI card for more than 250 ms.Alarm Data = Cabinet, Slot (C1,2) (S1through 10)35 MJD04 Red Alarm RecPCM carrier detected locally on PRIcards.Alarm Data = Cabinet, Slot (C1,2) (S1through 10)36 MJD05 Yellow AlarmRemotely detected failure transmitted inframe on PRI card.Alarm Data = Cabinet, Slot (C1,2) (S1through 10)37 MJD06 Yellow Alarm RecRemotely detected failure restoredtransmitted on PRI card.Alarm Data = Cabinet, Slot (C1,2) (S1through 10)38 MJD07 Blue AlarmAll one's being transmitted on facility onPRI card.Alarm Data = Cabinet, Slot (C1,2) (S1through 10)39 MJD08 Blue Alarm RecA blue alarm condition has beencleared.Alarm Data = Cabinet, Slot (C1,2) (S1through 10)