■ Devices that can be specified (indicated by ●)Operands WX WY WR WL SV EV DT LD In SWR SDTConstant Indexmodifier(Note 1)K HS1 ● ● ● ● ● ● ● ● ● ● ●S2 ● ● ● ● ● ● ● ● ● ● ●D ● ● ● ● ● ● ●n ● ● ● ● ● ● ● ● ● ●(Note 1) A character constant cannot be specified.■ Control data specificationSpecification of [S1]For [S1], specify the transfer method. The specification method differs depending on wordtransfer and bit transfer.[S1]:Transfer inword unitsSpecify the number of send wordsH001 to H1FB (1 to 507 words)H0[S1]:Transfer inbit unitsDestination bit No.(H0 to HF)H8 H0 (fixed)Master unit bit No.(H0 to HF)Specification of [S1+1]For [S1+1], specify the COM port number of a master unit and the unit number of a destinationunit.[S1+1]:COM port selection(H1/H2/HF/HE)Unit No. (H00 to H63, HEE)(0 to 99,238)H0 fixedCOM port selectionCOM ports can be selected as shown in the following table.COM port selection(upper four bits) H1 H2 HF HEPort number COM1 COM2 COM0 Port number specified for the F469 (UNITSEL)instruction8.1 Communication Instruction8-4 WUME-FP0HCOM-06