648 G8264 Command Reference for ENOS 8.4Virtual NIC Group ConfigurationThe following table describes the Virtual NIC (vNIC) Group configuration options.Table 370. vNIC Group Configuration OptionsCommand Syntax and Usagevnic vnicgroup <1‐32>Enters vNIC Group Configuration mode.Command mode: Global Configuration[no] enableEnables or disables the vNIC Group.Command mode: vNIC Group configuration[no] failoverEnables or disables uplink failover for the vNIC Group. Uplink Failover for thevNIC Group will disable only the affected vNIC links on the port. Other portfunctions continue to operate normally.The default setting is disabled.Command mode: vNIC Group configuration[no] member number>Adds or removes a vNIC to the vNIC Group. The vNIC ID is comprised of theport number and the vNIC number. For example: 1.1.Command mode: vNIC Group configuration[no] port number or alias>Adds or removes the selected switch port to the vNIC Group.Command mode: vNIC Group configuration[no] trunk <1‐64>Adds or removes the selected Link Aggregation Group (LAG) to the vNICGroup.Command mode: vNIC Group configurationvlan number>Assigns a VLAN to the vNIC Group.Command mode: vNIC Group configurationno vnic vnicgroup <1‐32>Deletes the selected vNIC Group.Command mode: Global configurationshow vnicgroupDisplays the current vNIC Group parameters.Command mode: All PreviousNext |