11-10 COPYRIGHT © 1999 CANON INC. CANON imageRUNNER 600 REV.1 JAN. 2000 PRINTED IN U.S.A.CHAPTER 11 INSTALLATIOND. Mounting the Corona AssembliesNo.12345WorkRemove the screw, and detach the frontcover of the transfer separation chargingassembly.Remove the metal fixing (1 screw), anddisconnect the connector.While pressing down on the front and therear of the transfer separation chargingassembly, pull it to the front then to theupper left to remove.Use alcohol solution, and clean thetransfer separation charging wire.Mount the transfer separation chargingassembly with the following in mind:• The charging assembly must becompletely dry.• The charging wire cleaning member isat the center.• The gut wire is not forced against thetransfer guide.• The grounding plate is positioned on theoutside of the frame. (See the diagramon the right.)Connect the connector of the transferseparation charging assembly, and mountthe metal fixing.Mount the front cover of the transferseparation charging assembly with ascrew.Push in the fixing/feeding assembly untilit locks in place.RemarksFront cover of the transfer separationcharging assemblyScrewScrewMetal fixingConnectorCharging assemblyGrounding plate