AMAX panel 2000 / AMAX panel 2000 EN System Functions | en 39Bosch Sicherheitssysteme GmbH Installation Manual F.01U.241.127 | V4 | 2011.126 System Functions6.1 Duress alarmThis function allows code holders to perform a keypad Duress Alarm.A Keypad Duress Alarm is used as a silent holdup alarm when 0 is added to the end of a validCode used to disarm the system.UserCodeInstallerCodeFunction Description• • 0 # Duress alarm (Refer to 6.1 )• • 1 # Siren test (Refer to 6.2 )• • 2 # Fault and Tamper analysis (Refer to 6.3 )• • 3 # View date and time (Refer to 6.4 )• • 4 # Walk test (Refer to 6.5 )• • 5 # Event memory recall (Refer to 6.6 )• • 6 # Reset panel/clear siren (Refer to 6.7 )• • 7 # Initiate a modem call (Refer to 6.8 )• • 8 # Send Test report (Refer to 6.9 )• • 9 # Bypass (inhibit) (Refer to 6.10 )• • 96 # Show Zone type (Refer to 6.11 )• 97 # Bypass all faults (Refer to 6.12 )• 98 #*Enable=# / Disable=* installer code user's access (Refer to6.13 )• • 99 # Change individual code (Refer to 6.14 )• 955 # Change/View date and time (Refer to 6.15 )• 956 # Add/delete a level 2 user (Refer to 6.16 )• 956 # Add/delete Remote Radio User Codes (Refer to 6.17 )• 957 # Change domestic phone numbers (Refer to 6.18 )• 958 # Enter Programming Mode (Refer to 6.19 )• 959 # Exits from installer’s programming mode without savingthe programmed data. (Refer to 6.20 )• 960 # Exits from installer’s programming mode with saving theprogrammed data. (Refer to 6.21 )• 961 # Resets the control panel to factory defaults. (Refer to6.22 )• 962 # Copies the control panel memory to the programming key.(Refer to 6.23 )• 963 # Copies the programming key data to the control panelmemory. (Refer to 6.24 )• 999 # Displays the software version number or control paneltype. (Refer to 6.25 )Default Pads on PCB Default the control panel with the hardware (Refer to6.26 )