AMAX panel 2000 / AMAX panel 2000 EN Installation | en 15Bosch Sicherheitssysteme GmbH Installation Manual F.01U.241.127 | V4 | 2011.12Enter the four-digit installer code (the factory default is 1234) + (958) and press [#] .Two beeps sound and the STAY and the AWAY indicators flash simultaneously to indicate thatyou have entered into installer’s programming mode.Once you enter into installer’s programming mode, you are automatially positioned at location000, the first digit of the IP Address/ primary telephone number for receiver 1. The keypadindicators display the current data stored in this location.Table 3.2 Keypad IndicatorsTo move to a different programming location:Enter the location number and press [#] .For example, press [1 7][#] to automatically position you at the beginning of the subscriber IDnumber 17 for receiver 1. The data stored in the new location appears.To move to the next location:Press [#] .For example, if you are currently positioned at location 017, press [#] to move to location018.To move to the previous location:Press [*] .For example, if you are positioned at location 018, press [*] to move back to Location 017.To change data in the current location:Enter the new value (0 - 15) and press [*] .The data is stored and you remain positioned at the same location. The keypad indicatorsdisplay the new value (for example, if you enter [1 4] and press [*] , the zone 4 and MAINSindicators are lit).To exit from installer’s programming mode + save data:Enter command [9 6 0] and press [#].Two beeps sound and the STAY and AWAY indicators are deactivated. The system returns tothe disarmed state and is now ready for use.Data Zone IndicatorsValue 1 2 3 4 5 6 7 8 Mains01 X2 X3 X4 X5 X6 X7 X8 X9 X X10 X11 X X12 X X13 X X14 X X15 X X