www.dadehpardazan.ir 88594014-155 Operation5.9.1 Absolute Data Request Signal (SEN)5-705.9 Absolute Linear ScalesIf using an absolute linear scale, a system to detect the absolute position can be designed for use with the hostcontroller. As a result, an operation can be performed without a zero point return operation immediately afterthe power is turned ON.For details on how to set up the absolute linear scale, refer to 5 Trial Operation (Checking Linear ServomotorOperation) in the-V Series User’s Manual, Setup, Linear Motor (No.: SIEP S800000 44).Set Pn002.2 to 0 (factory setting) to use the absolute linear scale.The SEN signal is not required when using the absolute linear scale as an incremental linear scale.5.9.1 Absolute Data Request Signal (SEN)The absolute data request signal (SEN) must be input to obtain absolute data as an output from the SERVO-PACK.The following table describes the SEN signal.The SEN signal is input at the following timing.Parameter Meaning WhenEnabled ClassificationPn002n.0[Factory setting]Uses the absolute linear scale as an absolute linearscale. After restart Setupn.1 Uses the absolute linear scale as an incremental linearscale.Type Signal Name ConnectorPin Number Setting MeaningInput SEN CN1-4OFF (low level) DisabledON (high level) The host controller sends a request tothe SERVOPACK for the absolute data.4.7 kΩSEN 4CN1SG2+5 V0 V100 Ω0 V0.1 μFHost controller SERVOPACKHigh level:Approx. 1 mA7406 or the equivalentWe recommend a PNP transistor.Analog