Toshiba Perfecptione Installation And Maintenance Manual
PROGRAMMINGPROCEDURESSECTION200-255-307FEBRUARY19927. There is a maximum of 500 Autodial a buttons per system.8. XXX = Fixed digits to be dialed (maximum: 16 digits/* = pause).9. This feature can on/y be assigned to 2000~series electronic/l OOO-series digital LCD telephones.IO. The Flash button causes a 500 ms or a 1-second flash to a CO trunk.11. XX = Leading one or two digits (1 - 9) designating the Hundreds Group to be activated on an associatedDSS console (switched operation only).12. LNNX = The port number of the electronic/digital telephone to be signaled.13. External Paging is used to access External Paging Zones (0 - 4).14. Internal Paging is used to access Internal Paging Groups (0, 2 - 17).15. SDC XX makes the station a controller of Station Speed Dial list XX (XX = 01 - 50).SDU XX makes the station a user of Station Speed Dial list XX (XX = 01 - 50).16. A System Night Button m can be assigned to one attendant-position electronic/digital telephone pertenant if an attendant console is not assigned to that tenant.17. XXXX = The DN of the station that is to receive a Voice Page.= Ignore line entered.= Backspace.= Stop printing and return to REQ.= Exit program.TABLE7-2 (continued)ErrorCodesI Program Name: Electronic Telephone Data Block (DEKT) IError Code MeaningEREKT 00 A PCB is not equipped at that location.~. EREKT 01 1 The PCB is an NSTU type (not an NEKU/NDKU).I I1 EREKT 02 1 The port is busy (REQ = CHG or OUT).EREKT 03 The port has already been assigned to a station, DSS console, or DDIU (REQ = NEW). IEREKT 04 1 1 was entered, but tenant service was not enabled in the Svstem Data Block.EREKT 05 1 was entered, but Attendant 1 was not programmed (no Attendant Data Block).EREKT 06 Wrong button number (over permitted button strip number).EREKT 07 Assigned port LNNX is not assigned as a station port (Manual Signaling).-.EREKT 08 1 The maximum number of m buttons has already been assigned (maximum: 500).EREKT 09 PUG was entered, but a Call Pickup Group number is not assigned.EREKT 10 The DN conflicts with existing DN.EREKT 11 510 DNs have already been assigned in the system.IEREKT12 1 The DN has already been assigned to its maximum number of appearances (Primary is 1,Secondary is 95).EREKT 13 “Call Pickup Group number = NONE” was entered, but m button has already been assigned.EREKT 14 The next hunt DN is not assigned.EREKT 15 A DN has already been assigned to the port.1 EREKT 16 1 The input DN has already been assigned to this station. IEREKT 17 The input data was erased because the program was aborted during a NEW data entry.EREKT 18 The port is not assigned.EREKT 19 The port is assianed to an NSTU PCB.7-11 |
Related manuals for Toshiba Perfecptione
This manual is suitable for:
Product
Menu
Learn More
Menu
Legal
Menu
Copyright © 2024 OneStart. All Rights Reserved