55 / 80Copyright © 2014 TOSHIBA TELI CORPORATION, All rights reserved. http://www.toshiba-teli.co.jp/index.htmD4235067DTimerControlThis section describes TimerControl category for the BG series.This camera series is able to generate Timer0Active signal, derived from exposure start, by register setting.This signal can be used as strobe control signal.EXT_TRIGExposureTIMER0 ACTIVEDelay Duration* ActiveLowEXPOSURE ACTIVEFig.5-10 Timer0Active● RegistersRegister Visibility Access DescriptionTimerSelector Expert R Returns the name of the timer that selected.TimerDuration Expert R/W Sets the width of Timer0Active signal.TimerDelay Expert R/W Sets the delay of Timer0Active signal.TimerTriggerSource Expert R Returns the timing that is the basic of the timer● Setting- Set the width of Timer0Active pulseSet the following value to “TimerDuration” register. Setting value is Float type.Pulse width ValueMinimun (*) 0.00[μs]Maximum 2000000.00[μs]* initial factory setting