50 / 80Copyright © 2014 TOSHIBA TELI CORPORATION, All rights reserved. http://www.toshiba-teli.co.jp/index.htmD4235067D- Changes trigger polarity (HardwareTrigger operation only)Set the following value to “TriggerActivation” register. Setting value is Enumeration type.Value PolarityFallingEdge (*) NegativeRisingEdge Positive* initial factory setting- Sets trigger delay (HardwareTrigger operation only)Set the following value to “TriggerDelay” register. Setting value is Float type.Adds delay time from trigger edge to exposure start.TriggerDelay ValueMinimum (*) 0.00[μs]Maximum 4095.00[μs]* initial factory setting- Sets sampling period for Anti-Chattering (HardwareTrigger operation only)Set the following value to “TriggerSamplingPeriod” register. Setting value is Float type.TriggerSamplingPeriod[μs] ValueMinimum (*) 2.00[μs]Maximum 1000.00[μs]* initial factory setting● NoteChanging “TriggerMode”, “TriggerSource”, “TriggerActivation” registers value is invalid during image streamdata output.In SoftwareTrigger operation, it takes less than 1ms from “TriggerSoftware” command to exposure start.When set longer value to “TriggerSamplingPeriod” register, noise immunity of trigger input line is improved,but the delay time of receiving trigger signal become longer.