NCK alarms11/2006 Overview of Alarms2-555© Siemens AG, 2006. All rights reservedSINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition61521 Channel %1 block %2: Current grinding wheel too wideParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycles: CYCLE411, CYCLE415Remedy: Reduce width of grinding wheel61522 Channel %1 block %2: Overlap >= current grinding wheel widthParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycle: CYCLE411Remedy: Reduce overlap61523 Channel %1 block %2: Zero signal of calipers missingParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE413Remedy: Check calipers signal61524 Channel %1 block %2: Incorrect oblique angleParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycle: CYCLE413Remedy: Oblique plunge angles must be >-90° and <90°61525 Channel %1 block %2: Incorrect grinding wheel typeParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycle: CYCLE413Remedy: Change grinding wheel type $TC_TPC161526 Channel %1 block %2: Workpiece radius = 0Parameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycle: CYCLE414Remedy: Enter workpiece radius > 061527 Channel %1 block %2: Grinding wheel radius >= workpiece radiusParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycle: CYCLE414Remedy: Change grinding wheel radius or workpiece radius61529 Channel %1 block %2: Dimensional notation INCH programmedParameters: %1 = Channel number%2 = Block number, label channel numberDefinitions: The alarm can be triggered by the following grinding cycles: CYCLE410, CYCLE411, CYCLE412,CYCLE413, CYCLE414, CYCLE415, CYCLE420Remedy: Basic system MD $MN_SCALING_SYSTEM_IS_METRIC does not correspond to programmed Gcommand (G group 13).