NCK alarms11/2006 Overview of Alarms2-341© Siemens AG, 2006. All rights reservedSINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition17224 Channel %1 block %2 tool T/D= %3 - tool type %4 is not permittedParameters: %1 = Channel number%2 = Block number, label%3 = Incorrect T no. / D no.%4 = Incorrect tool typeDefinitions: On this system, it is not possible to select tool offsets of theindicated tool types.The variety of tool types can both be limited by the machine OEMand be reduced on individual control models.Only use tools of the tool types permitted for this system.Check whether an error has occurred on defining the tool.Reaction: Correction block is reorganized.Interpreter stopInterface signals are set.Alarm display.Remedy: Correct the NC program or correct the tool dataProgramContinuation:Clear alarm with NC START or RESET key and continue the program.17230 Channel %1 block %2 Duplo no. already assignedParameters: %1 = Channel number%2 = Block number, labelDefinitions: If an attempt is made to write a tool Duplo number to the name of which another tool (another Tnumber) already exists with the same Duplo number.Reaction: Correction block is reorganized.Interface signals are set.Alarm display.Remedy: Correct the NC program.ProgramContinuation:Clear alarm with NC START or RESET key and continue the program.17240 Channel %1 block %2 illegal tool definitionParameters: %1 = Channel number%2 = Block number, labelDefinitions: If an attempt is made to modify a tool data that would subsequently damage the data consistency orlead to a conflicting definition, this alarm will appear.Reaction: Correction block is reorganized.Interface signals are set.Alarm display.Remedy: Correct the NC program.ProgramContinuation:Clear alarm with NC START or RESET key and continue the program.17250 Channel %1 block %2 illegal magazine definitionParameters: %1 = Channel number%2 = Block number, labelDefinitions: If an attempt is made to modify a magazine data that would subsequently damage the dataconsistency or lead to a conflicting definition, this alarm will appear.Reaction: Correction block is reorganized.Interface signals are set.Alarm display.Remedy: Correct the NC program.ProgramContinuation:Clear alarm with NC START or RESET key and continue the program.