Overview of Alarms 11/2006NCK alarms2-374© Siemens AG, 2006. All rights reservedSINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition20103 Channel %1: Digitizing module does not support 3+2 axes digitizingParameters: %1 = Channel numberDefinitions: Prerequisite for 3+2 axis digitizing is that the NCU and the digitizing module both have the 3+2 axismode.Reaction: Interface signals are set.Alarm display.Remedy: - SW update for the digitizing module.- Select 3-axis mode for the digitizing via machine data.ProgramContinuation:Clear alarm with the Delete key or NC START.20105 Channel %1: axes stopped by digitizer. Error code: %2Parameters: %1 = Channel number%2 = Error code of digitizing unitDefinitions: The digitizing unit has recognized an error in the communication and signaled this to the NC.Reaction: Channel not ready.NC Start disable in this channel.Interface signals are set.Alarm display.NC Stop on alarm.Remedy: Please inform the authorized personnel/service department. Error code 1: Check cable connectionleading to the digitizing unit. Other error codes: See manual for digitizing unit.ProgramContinuation:Clear alarm with the RESET key. Restart part program20106 Emergency stop set by the digitizerDefinitions: The digitizing unit has recognized a serious error and triggered an emergency stop. Cause: Seedisplay on the digitizing unit.Reaction: Channel not ready.NC Start disable in this channel.Interface signals are set.Alarm display.NC Stop on alarm.Remedy: -ProgramContinuation:Clear alarm with the RESET key. Restart part program20108 Invalid data package received from the digitizer. Error codes %1, %2Parameters: %1 = Error code of cyclic packet%2 = Error code of out-of-band packetDefinitions: A data packet received by the digitizing unit could not be evaluated.Reaction: Channel not ready.NC Start disable in this channel.Interface signals are set.Alarm display.NC Stop on alarm.Remedy: Please inform the authorized personnel/service department. Error code: 0, 0: Check cable connectionleading to the NC. Other error codes: e.g. wrong header, incorrect checksum (developmentdocumentation).ProgramContinuation:Clear alarm with the RESET key. Restart part program