3–Fibre Channel ConfigurationSetting an FA-PWWN65 BK3254601-00 CAfter refreshing the Brocade® switch, the Port Info page shows the PortName as shown in Figure 3-18.Figure 3-18. New FA-PWNN Port Name in GUISetting FA-PWWN with QConvergeConsole CLITo set the FA-PWWN from the adapter using QConvergeConsole CLI:1. In interactive mode of QConvergeConsole CLI, select Main Menu, and thenclick Adapter Configuration.2. Select HBA Parameters.3. Select the appropriate port.4. Select Configuration HBA Parameters.5. Select Enable Fabric Assign WWN.6. On the Enable Fabric Assign WWN Menu, select 1: Enable.7. Select the option to Commit Changes.The following shows an example of setting the FA-PWWN:HBA Desc. : QLE2742 QLogic 2-port 32Gb Fibre Channel AdapterFW Version : 7.04.00WWPN : 21-00-00-OE-1E-11-4A-38WWNN : 21-00-00-OE-1E-11-4A-38Link : Online===============================================================1: Connection Options2: Data Rate3: Frame Size4: Enable HBA Hard Loop ID5: Hard Loop ID6: Loop Reset Delay (seconds)