78• Are there contradictions between the address and thenetwork subnet to be accessed?When this unit and the client PC are in the same sub-net, are the IP addresses of this unit and the client PCset in same subnet? Or is "Use Proxy Server" for thesettings of the browser checked? When accessingthis unit in the same subnet, entering the address ofthis unit in the "Don’t Use Proxy For TheseAddresses" box is recommended.Cause/solution• Is the same IP address provided to other devices?Refer to a system administrator for further informa-tion.• Are you accessing the wrong IP address?Check the connection as follows:>ping "IP address of this unit"If there is reply from this unit, the connection is nor-mal. If not, check the settings of the IP address andthe subnet mask.• Is the valid IP address set?Refer to a system administrator for further informa-tion.• Is the connection indicator of the 10BASE-T/-100BASE-TX port lit? When it is not lit, connection toa LAN is not established or a network is not workingcorrectly.Confirm that the connection indicator of the 10BASE-T/100BASE-TX port is lit. Refer to a system adminis-trator if it is not lit.• Is the Ethernet cable firmly connected to the 10BASE-T/100BASE-TX port?Confirm the cable is firmly connected.TroubleshootingBefore asking for repairs, check the symptoms with the following table.Contact your dealer if a problem cannot be solved even after checking and trying the solution or a problem is notdescribed below, and when having a problem with installations.Referencepages–SymptomCannot access from thebrowser.–2828–28