Installation Instructions Section 26 Part Number 000007646 11/10ElectricalSPECIFICATIONS*120 Volts – 60 Hz. – 1.8 amp (U.S. Standard) (Eight foot cord withplug is included with the U.S. Standard unit)GROUNDING INSTRUCTIONSThis appliance must be grounded. In the event ofmalfunction or breakdown, grounding provides a path ofleast resistance for electric current to reduce the risk ofelectric shock. This appliance is equipped with a cordhaving an equipment-grounding conductor and agrounding plug. The plug must be plugged into anappropriate outlet that is properly installed and groundedin accordance with all local codes and ordinances.! WarningAll wiring must conform to local, state and nationalcodes.ElectricVoltage –Cycle – Amp.*120 Volt – 50/60 Hz./1 Ph. – 1.8 amp220 Volt – 50/60 Hz./1 Ph. – 1.8 amp230 Volt – 60 Hz./1 Ph. – 1.8 amp240 Volt – 50 Hz./1 Ph. – 1.8 ampMotorHorsepower 1/7 HPFuse Size 15 amp maximumShip Weight 187 poundsOperatingTemperatureRange40°F minimum – 110°F maximum(4° – 43°C)! WarningThe dispenser must be grounded in accordancewith national and local electrical codes.! WarningImproper connection of the equipment-groundingconductor can result in a risk of electric shock. Theconductor with insulation having an outer surfacethat is green with or without yellow stripes is theequipment grounding conductor. If repair orreplacement of the cord or plug is necessary, do notconnect the equipment-grounding conductor to alive terminal. Check with a qualified electrician orserviceman if the grounding instructions are notcompletely understood, or if in doubt as to whetherthe appliance is properly grounded. Do not modifythe plug provided with the appliance — if it will not fitthe outlet, have a proper outlet installed by aqualified electrician.