If you have any questions concerning this bulletin, please contact Manitowoc Beverage Equipment’s Technical Service Department at (800) 367-4233503170309/29/05 REV 1Installation InstructionsFLAVOR MAGIC COVER EXCHANGE PROCEDUREFIGURE 1FIGURE 2FIGURE 3FIGURE 41. Disconnect power to ice drink dispenser.2. Remove translite and lamps in work area.3. Remove and discard vinyl lines from retainer in cover andfrom valves. Clean up any syrup spills.4. Disconnect ribbon connector on cover touchpad (A) andLED from harness (B) connected to circuit board. Discon-nect harness from circuit board and discard (C).5. If chute bracket (D) present go to step 6. Loosen right chutebracket (E) mounting screw and attach bracket chute (D).CAUTION: DO NOT STRESS PLASTIC COMPONENTSIN THIS AREA TO AVOID BREAKAGE.6. Loosen screws (F) holding cover assembly to cover bracketand cover bracket (G) to chute bracket (D). Remove anddiscard cover assembly & cover bracket.7. Tighten right rocking chute bracket screw (if applicable).8. Route the four (4) vinyl lines extending from the back of thecover pad assembly through the opening between the mer-chandiser bottom and rocking chute.