6TAKEOFF TOUR190-00357-00 Rev GInstrument Panel Self-TestOnce the database has been acknowledged, theInstrument Panel Self-Test Page appears. To ensurethat your 500W-series unit and any connected instru-ments are working properly, check for the followingindications on your CDI/HSI, RMI, external annuncia-tors and other connected instruments:• Course deviation• Glideslope• TO/FROM flag• Time to destination• Bearing to destination• Desired track• Distance to dest.• Ground speed• All external annunciators (if installed)The Instrument Panel Self-Test Page indicates thecurrently selected OBS course, fuel capacity (CAP),fuel on board (FOB) and fuel flow (FF). The fuelcapacity is entered manually. Fuel on board and fuelflow may be manually entered if your installation doesnot include connection to sensors which automaticallyprovide these figures.To enter fuel capacity, fuel on board or fuel flowfigures (if not provided by sensors):1. Turn the large right knob to select the “CAP”,“FOB” or “FF” field.2. Turn the small and large right knobs to enterthe desired figure, then press ENT.Enter the fuel capacity, fuel on board or fuel flow figuresdirectly onto the appropriate field of the Instrument PanelSelf-Test Page. Fuel on board and fuel flow are automaticallyprovided if your installation includes connection to externalsensors.Check CDI/HSI,RMI and other in-struments to verifythese indications.Should matchcurrent OBS courseselection Select to displayChecklists PageSelect to Set Fuel Levelto Full CapacityFuel Capacity isentered manuallyFuel on board and fuel flow areprovided manually or by sen-sors, if installedInstrument Panel Self-Test