Chapter 22-372.8 Pickup/Feeding System2.8.1 Registering theCassette/MultifeederPaper Width BasicSetting (under 'FUNC') 0002-4304CLC5100 / CLC4000You must register the paper width basic setting if youhave Replaced the paper width VR of the copier(including the multifeeder). Adjusted the front/rear registration for the cassette.For the cassette, you must register the setting for'STMTR' and 'A4R'; for the multifeeder, you mustregister the setting for 'A6R', 'A4R', and 'A4'.᤹a. Cassette 1 or 21) Slide out the cassette you want to register thesetting for, and set the paper width guide plateinside the cassette to A4R.2) Set the cassette in the copier.3) Check that the basic setting is indicated on the'CSTAD' screen of 'FUNC' in service mode on thecontrol panel.4) Select the size of the cassette for which you want toregister the basic setting:UPA4R (cassette 1)LOWA4R (cassette 2)5) Note that basic setting 1 has been registered.6) Slide out the cassette you want to register thesetting for, and set the paper width guide plateinside the cassette to STMTR.7) Set the cassette in the copier.8) Check that the basic setting is indicated on the'CSTAD' screen of 'FUNC' in service mode on thecontrol panel.9) Select the size of the cassette for which you want toregister the basic setting:UPSTMTRLOWSTMTR10) Note that basic setting 2 has been registered.᤹b. Multifeeder1) Set the paper guide plate [1] of the multifeeder toA4R (210 mm).2) Note that the basic setting is indicated on the 'CSTAD' screen for 'FUNC' in service mode on thecontrol panel.3) Select the size for which you want to register thebasic setting.MFA4R4) Note that basic setting 1 has been registered.5) Set the paper guide plate [1] of the multifeeder toA6R (105 mm) [3].᤹F-2-50᤹6) Check that the basic setting is indicated on the'CSTAD' screen under 'FUNC' in service mode onthe control panel.7) Select the size for which you want to register thebasic setting.MFA6R8) Note that basic setting 2 has been registered.9) Set the paper guide plate of the multifeeder to A4(297 mm).10) The basic setting is indicated on the 'CSTAD'screen under 'FUNC' in service mode on the controlpanel.11) Select the size for which you want to register thebasic setting.105mm[3] [2][1]