Chapter 22-122.3 Scanning System2.3.1 When Replacing theScanning Lamp,Standard White Plate,Lamp Regulator,Reflecting Lamp Cover,Reader Controller PCB,Flash memory on Readercontroller PCB, orAnalog Processor PCBCCD Unit 0002-5743CLC5100 / CLC40001) Execute data reading using 'CCD' under 'FUNC' inservice mode.2.3.2 Routing the ScannerCable 0002-6049CLC5100 / CLC4000 You must keep the mirror positioning tool (FY93040000) near at hand before routing the scannercable.1) Remove the left cover and the hopper left cover.2) Remove the control panel.3) Remove the vertical size plate and the right glassretainer right, and remove the copyboard glass.4) Move the No. 2 mirror mount until the pulley shaft[1] of the No. 2 mirror mount is visible through thelong hole [2] in the side plate.F-2-20᤹F-2-21᤹5) Fit a binding screw (M4 × 8mm) [3] to the pulleyshaft [4] to fix the front and rear of the pulleytemporarily to the side plate [5], therebytemporarily fixing the No. 2 mirror mount in place.᤹F-2-22᤹[1][2][1] [2][5][4][3][5][3][4]