Easy Series Device Specifications and Overview | en 97Bosch Security Systems, Inc. System Reference Guide F01U087835 | 02 | 2008.103. Determine the sensitivity setting for your application.Refer to Table 10.12.Table 10.12 wLSN Glassbreak Detector Sensitivity Settings4. Use a small screwdriver to move the sensitivity switches. Use the settings determined inStep 3.5. Turn on any sources of noise (such as machinery, office, or audio equipment) in the area.6. Observe the green event LED (Item 6, Figure 10.9 on Page 95) for approximately 1 min. Ifthe green LED flashes, relocate the unit or reduce the sensitivity by adjusting thesensitivity switch.7. Repeat Steps 3 through 6 until you achieve the best sensitivity level.8. After setting the sensitivity, slide the LED enable switch (Item 8, Figure 10.9 on Page 95)to the OFF position.TestingTest the detector at least once each year. Test the detector with the 13-332 Sound SensorTester.Figure 10.11 13-332 Sound Sensor TesterSensitivity SENS1 SENS2 Approximate RangeMaximum OFF OFF 7,6 mMedium ON OFF 4,6 mLow OFF ON 3 mLowest ON ON 1,5 m1 Activate/Test switch2 Start button3 Flex/Man switch