52 en | Programming Easy SeriesF01U087835 | 02 | 2008.10 System Reference Guide Bosch Security Systems, Inc.Global Report Routing Items5.2.6 Point Programming ItemsProgramming Item ItemNumberSelections Manuf.DefaultCommunicator Disable 304 0 = Enable reporting1 = Disable reporting (local-only system)0Route Attempts 305 1 to 20 10Send Reports During Walk Test 306 0 = No reports1 = Only Walk Test Start and Walk Test End reports0Default = Country-specific default. Select this programming item to hear the updated default value, or refer to Section 11.3 CountryCode Specific Default Programming Codes, page 108 .Programming Item Number(bold digits = Point Number)Programming Item Selections9011, 9021, 9031, 9041...9101...9151...9201...9321Point Type 0 = Disabled1 = Perimeter2 = Interior3 = Perimeter Instant4 = 24-Hour5 = Fire Verified*6 = Fire Instant7 = Silent Panic8 = Interior Walkthrough9 = Perimeter Exit Cancel11 = Momentary Keyswitch12 = Maintained Keyswitch13 = 24-Hour Trouble14 = User Emergency9012, 9022, 9032, 9042...9102...9152...9202...9322Circuit Style 0 = Dual 2.2 kΩ alarm and tamper circuit2 = Single 2.2 kΩ alarm circuit9013, 9023, 9033, 9043...9103...9153...9203...9323Include in Custom Protection 0 = Point not included1 = Point included9014, 9024, 9034, 9044...9104...9154...9204...9324Cross Zone/Exit Route 0 = Cross zoning disabled, point is on the exitroute.1 = Cross zoning enabled, point is on the exitroute2 = Cross zoning disabled, point is not on the exitroute (must force arm).3 = Cross zoning enabled, point is not on the exitroute.9015, 9025, 9035, 9045...9105...9155...9205...9325Response Time 1 to 10 in 50 ms increments