e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE © December 2005 TOSHIBA TEC2 - 56<>• The following items are displayed or set by using sub-codes at PM management setting in the tablebelow.0: Present number of output pages- Means the present number of output pages.1: Recommended number of output pages for replacement- Means the recommended number of output pages for replacement.3: Present driving counts- Means the present drive counts (1 count = 2 seconds).4: Recommended driving counts to be replaced- Means the recommended drive counts for replacement (1 count = 2 seconds).6: Present output pages for control- Means the present number of output pages for controlling.7: Present driving counts for control- Means the present drive counts for controlling (1 count = 2 seconds).Notes:• Sub-code 3 is equivalent to sub-code 7.When the value of sub-code 3 is changed, the value of sub-code 7 is also updated and viceversa.• Sub-code 0 is equivalent to sub-code 6.When the value of sub-code 0 is changed, the value of sub-code 6 is also updated and viceversa.• When “0” is set at one of sub-codes 0, 3, 6 and 7, the rest of them are automatically updatedto “0”.06/05 PreviousNext |