e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE © December 2005 TOSHIBA TEC2 - 46486 Laser Timing of auto-clearing ofpolygonal motor pre-run-ning rotationALL 0<0-2>SYS Switches the polygonalmotor to the standbyrotation when a certainperiod of time haspassed from the pre-running. At this code,the period to switch thestatus to the standbyrotation is set.0: 15 sec.1: 30 sec.2: 45 sec.* This setting is effec-tive when “0” or “2”is set at 08-483.1502 Image Error diffusion and dithersetting at photo modePPC 1<0-1>SYS Sets the image repro-duction method atphoto mode.0: Error diffusion1: Dither1515 Fuser Temperature setting ofwarming-up(Center thermistor)ALL 9<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1516 Fuser Temperature setting ofwarming-up(Side thermistor)ALL 9<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1520 Fuser Fuser roller temperatureduring printing(Center thermistor/Enve-lope)ALL 9<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1521 Fuser Fuser roller temperatureduring printing(Side thermistor/Envelope)ALL 9<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1Setting mode (08)Code Classifi-cation Items Func-tionDefaultablevalue>RAM Contents Proce-dure06/05 PreviousNext |