e-STUDIO163/203 ERROR CODE AND SELF-DIAGNOSTIC MODE © December 2005 TOSHIBA TEC2 - 42424-0 Fuser Temperaturedrop switchingtime setting inready status(Center ther-mistor)The firstdropALL 15<2-60>M This code is valid onlywhen “20” is set to 08-886.Setting value x 1 min.:from 2 to 60 min. later4424-1 The sec-ond dropALL 15<2-60>M 4424-2 The thirddropALL 15<2-60>M 4424-3 The fourthdropALL 15<2-60>M 4425-0 Fuser Temperaturedrop switchingtime setting inready status(Side ther-mistor)The firstdropALL 15<2-60>M 4425-1 The sec-ond dropALL 15<2-60>M 4425-2 The thirddropALL 15<2-60>M 4425-3 The fourthdropALL 15<2-60>M 4433-0 Fuser Temperaturecontrol lowerlimit(Plain paper/at ordinarytemperature)CenterthermistorALL 5<0-12>M 0: 130°C 1: 135°C2: 140°C 3: 145°C4: 150°C 5: 155°C6: 160°C 7: 165°C8: 170°C 9: 175°C10: 180°C11: 185°C12: 120°C4433-1 Side ther-mistorALL 3<0-12>M 4437 Fuser Fuser roller temperatureduring printing(Center thermistor /Thickpaper 2)ALL 9<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1438 Fuser Fuser roller temperatureduring printing(Center thermistor/OHPfilm)ALL 6<0-14>M 0: 140°C 1: 145°C2: 150°C 3: 155°C4: 160°C 5: 165°C6: 170°C 7: 175°C8: 180°C 9: 185°C10: 190°C11: 195°C12: 200°C13: 205°C14: 210°C1439 Fuser Pre-running time for firstprinting(Thick paper 2)ALL 10<0-15>M 0: Invalid 1: 1 sec.2: 2 sec. 3: 3 sec.4: 4 sec. 5: 5 sec.6: 6 sec. 7: 7 sec.8: 8 sec. 9: 9 sec.10: 10 sec.11: 12 sec.12: 14 sec.13: 16 sec.14: 18 sec.15: 20 sec.1Setting mode (08)Code Classifi-cation Items Func-tionDefaultablevalue>RAM Contents Proce-dure PreviousNext |