4. TroubleshootingEngine Test Routines• Diagnostics > Engine Diagnostics > Engine Test RoutinesPurpose To perform test routines for the engine.Operation Procedure When the main Engine Test Routines window displays, users can navigate through the list of routinesthat display along with their descriptions. Users can also directly input an EDC code to the text box tofind a routine. Users can select a maximum of 3 routines at the same time.After selecting one or multiple routines, pressing the “OK” button will open the test window that listsselected routines. Users can start/stop a desired test routine.Code Display Meaning100-0000 Main BLDC Motor Main BLDC Motor is On/Off100-0010 Main BLDC Motor Ready Detect if Main BLDC Motor runs at normal speed100-0041 OPC Motor Y Yellow Opc BLDC Motor is On/Off100-0042 OPC Motor M Magenta Opc BLDC Motor is On/Off100-0043 OPC Motor C Cyan Opc BLDC Motor is On/Off100-0044 OPC Motor K Black Opc BLDC Motor is On/Off100-0046 Y OPC Motor Ready Detect if Yellow OPC BLDC Motor runs at normalspeed100-0047 M OPC Motor Ready Detect if Magenta OPC BLDC Motor runs at normalspeed100-0048 C OPC Motor Ready Detect if Cyan OPC BLDC Motor runs at normal speed100-0049 K OPC Motor Ready Detect if Black OPC BLDC Motor runs at normal speed100-0080 T1 Engage Motor T1 Engage Motor On/Off100-0090 T1 Engae Sensor Detect if the T1 Engage is On or Off.100-0120 Exit Motor Forward Fast Exit Motor Forward Fast On/Off100-0130 Exit Motor Forward Slow Exit Motor Forward Slow On/Off100-0131 Exit Motor Backward Exit Motor Forward Backward On/Off100-0132 Exit Motor Backward Slow Exit Motor Forward Backward Slow On/Off100-0140 Duplex Motor Forward Duplex Motor Forward On/Off100-0141 Duplex Motor Forward Slow Duplex Motor Forward Slow On/Off100-0160 Duplex Fan1 Run Start/Stop Duplex Fan1 run100-0180 Dupelx Fan1 Run Ready Detects if Duplex Fan1 runs at normal speed.100-0200 T1 Elevating Motor T1 Elevate Motor On/Off100-0210 T2 Elevating Motor T2 Elevate Motor On/Off (Optional)100-0220 T3 Elevating Motor T3 Elevate Motor On/Off (Optional)100-0230 T4 Elevating Motor T4 Elevate Motor On/Off (Optional)100-0240 Waste Toner Motor Waste Toner Motor On/Off100-0241 Waste Toner Led Waste Toner Led On/Off100-0250 Waste Toner Full Sensor Detect if the waste toner is full or not.100-0260 SMPS Fan Run Start/Stop Deve. Fan run100-0270 SMPS Fan Run Ready Detects if Deve Fan runs at normal speed.100-0340 Feed Motor Feed Motor is On/Off100-0370 Tray1 Pickup Motor Tray1 Motor is On/OffCopyright© 1995-2016 SAMSUNG. All rights reserved. 4-24