47EnglishField Setting ModeClassification Function DetailCode(Main+ submenu)Basic Min. Max. Step UnitWater LawAuto heating of wiredremote controller WL type 2041 1(WL1) 1 2 - -Use of thermostat - 2091 0(No) 0 2 - -DHWActivating hot waterfunction DHW application 3011 0(No) 0 1(Yes) - -Heating modeMax. 3021 70 45 75 1 °CStop 3022 2 0 10 1 °CStart 3023 5 5 20 1 °CMinimum HeatingOperation time 3024 5 1 20 1 min.DHW operation time 3025 30 5 95 5 min.Heating operation time 3026 3 0.5 10 0.5 hourBooster heaterOperation 3031 1 (On) 0 (Off) 1 - -Delayed time 3032 20 20 95 5 min.Overshoot 3033 0 0 4 1 °CDisinfectionOperation 3041 1 (Yes) 0 (No) 1 - -Operation interval 3042 Fri (5) Sun(0) AllDay (7) - dayStart time 3043 23 0 23 1 hourTarget temp. 3044 70 60 75 5 °CHolding time 3045 10 5 60 5 minMax. operation time 3046 ߩ 1 24 1 hourSolar heat panel / defrostsignalSolar heat panelH/P interlocking /defrost signal3061 0 0 3 - -Heating Heating modeHeating/hot waterpriority 4011 0 (Hotwater) 0 1(Heating) - -Heating priority 4012 0 -15 20 1 °CHeating Off 4013 35 14 35 1 °COthers Outing modeTemperature of coolingwater oulet 5011 - - - 1 °CRoom Temperature ofcooling Mode 5012 - - - 1 °CTemperature of heatingleaving water 5013 25 25 ߡߩ 1 °C