26Special Installation (Mounting to fittings)3.4 Special InstallationThe unit can be hung from or embedded in a wall. However, some installations impose additional limitations onoperating temperatures and other factors.Examine installation methods and the ambient conditions for your installation site. Refer to sections “3.1 InstallationSite Requirements” (pg. 16), ”3.2 Installation Conditions” (pg. 18), and “3.3 Installation Procedures” (pg. 22) in thismanual.Measurements discussed in this manual assume the following conditions:• A 100 % white input is supplied.• Sufficient aging has been completed.Make all measurements under identical conditions. The aging period required for correct measurementis about two and a half hours, depending on the time available at the installation site.3.4.1 Mounting to fittingsObserve the following guidelines when mounting the unit to fittings.Notes 2 to 8 apply to all cases of mounting to fittings.1 Remove any objects from around the panel within a distance of300 mm.2 Any unit deformation/warping occurring as a result of installationshould be less than 4 mm.3 Never block or cover vents or other openings aside from thoseshown as blocked in the illustrations on the following page.4 The fittings should have a thickness of less than 20 mm.(This limit does NOT apply to fitting in examples 1, 3, 5, and 6 onthe following page.)5 L-shaped fittings should have a thickness of less than 100 mm.6 The strength of the fittings should be adequate to bear the weightof the display.7 Take precautions to avoid sharply bending the power cable.8 If necessary, remove the handles. When reinstalling the handles,completely tighten the screws for safety.✩ Operating environment for standard installation• Ambient Temperature: 0 °C to 40 °C (examples 1 to 3)✩ Operating environment for vertical installation (*1, *2)• Ambient Temperature: 0 °C to 40 °C (vertical installation:examples 4 to 6)✩ Operating temperatures for Upside-Down Installations (*1, *2)• Ambient Temperature: 0 °C to 40 °C (examples 1 to 3)The operating temperature restrictions for the speaker system (PDP-S44-LR) are the same regardless of whether installation is horizontalor vertical.*1 For this installation, set the ‘FAN CONTROL’ to ‘MAX’ as shown in “5.4.3Adjustment and Setting in the Integrator Mode 14) Cooling Fan ControlSetting (pg. 172)”.*2 When INPUT2 has been selected, use input compatible signal up to1280x1024 (60 Hz) at ambient temperature condition of 0 °C to 35 °C.NoteWhen a video card other than PDA-5003/PDA-5004 is used, the operatingtemperature conditions given above may vary. Check the video cardoperating instructions for the conditions.Arrange the powercable so that minimumstress is placed on it.Less than100 mm L-shaped fittingLess than20 mm(No thickness limitations in examples 2and 4 on the following page.)Less than20 mm(No thickness limitations in examples 2and 4 on the following page.)Maximum allowable deformation/warping is 4 mm.4 mm MAX