57Configure the settings relating to the alarm output terminal [Alarm]Click the [Alarm] tab on the "Alarm" page. ( pages 20 and 21: How to display/operate the setup menu)The settings relating to the alarm output terminal can be configured in this section. The settings for the alarm outputterminal can be configured only when "Alarm output" is selected for "Terminal 2" of "Alarm". Refer to pages 54 and55 for further information about the settings relating to the alarm action, and the alarm image. Alarm output terminal setup[Alarm output trigger]Select "On" or "Off" to determine whether or not to out-put the alarm signals to the alarm output terminal whenan alarm is detected.Default: Off[Alarm output type]Select "Latch" or "Pulse" for the alarm output terminal atan alarm occurrence.Latch: When an alarm is detected, the alarm output ter-minal will be in the state selected for "Trigger output"until the alarm occurrence indication button isclicked.Pulse: When an alarm is detected, the alarm output ter-minal will be in the state to the "Trigger output" set-ting for the period set for "Pulse width".Default: Latch[Trigger output]Select "Open" or "Close" to determine whether to openor close the alarm output terminal when outputting thealarm signals.Open: The alarm output terminal will open when out-putting the alarm signals. (Normally close)Close: The alarm output terminal will close when out-putting the alarm signals. (Normally open)Default: CloseNote:• When "Open" is selected, the alarm signal will beoutput for around 20 seconds when the power of thecamera is turned on.[Pulse width]When "Pulse" is selected for "Alarm output type", selectan alarm output terminal duration from the following.Available range: 1 - 120secDefault: 1sec