Keysight E1406A User Manual and SCPI Programing Guide 261VXI Subsystem Keysight E1406A Command ReferenceComments– byte, cmd_word, event_number, hand_id, int_id, line_number,logical_address, modid, and response_mask may be specified in decimal,hex (#H), octal (#Q), or binary (#B) formats.– end_bit selects whether the END bit is set in the command.– top_level selects whether the Top_level bit is set in the command.– enable selects whether the Enable bit is set in the command.– Related Commands: VXI:SELect, VXI:WSProtocol:RESPonse?,VXI:WSProtocol:QUERy?:WSProtocol:MESSage:RECeive?VXI:WSProtocol:MESSage:RECeive? receives a messagefrom the selected logical address using both the word serial protocol and thebyte transfer protocol.ParametersComments– The command will always terminate on the End bit being set. Additionaltermination options are on a specified number of bytes (count), or on amatch to a particular terminator (That is, LF, CRLF, END).– The response is returned as a string.– Related Commands: VXI:SELect, VXI:WSProtocol:MESSage:SENDParameterNameParameterType Range of ValuesDefaultUnits numeric count | LF | CRLF | END END