LYNX Touch Installation and Setup Guide- 24 -Programming the ControlProgram the Communications ModuleThe following system options are programmed in this section:Option FunctionCommunications Path Selects type of Communications ModulePrimary City Id Enter Central Station Primary City IDPrimary Central Station Id Enter Primary Central Station IDPrimary Subscriber Id Enter Central Station Primary Subscriber IDSupervision Selects how often the Communications Module sends a supervisory message to the CentralStation.Old Alarm Time Selects how long an undeliverable alarm delivery is retried to the Central Station.Remote Acc. IP or GSM Enables or disables user remote access via internet and/or GSM.Multi Mode IP or GSM (appears only if Remote Access IP or GSM is enabled.) Enables or disables multi modefeature.IP Fault Time (Appears only if IP is enabled in Communications Path field.) Selects time delay before theCommunications Module notifies the control panel of a loss of contact with the internet.Use DHCP Dynamically selects the IP addressesNIC IP Address (Appears only if “No” is selected in Use DHCP field.) Enter NIC IP Address.Subnet Mask (Appears only if “No” is selected in Use DHCP field.) Enter Subnet Address.Gateway IP Address (Appears only if “No” is selected in Use DHCP field.) Enter Gateway IP AddressDNS Server IP Address (Appears only if “No” is selected in Use DHCP field.) Enter Domain Name Server IPAddress.GSM Fault Time (Appears only if GSM is enabled in Communications Path field.) Selects time delay beforethe Communications Module notifies the control panel of a loss of contact with the network.GSM Rollover Allows messages to be sent over GSM in the event that contact with the internet is lost.GSM 24 Hour Test Enables daily test of GSM module operation.Note: If applicable, preprogrammed defaults for the LYNX Touch Control are shown on the screen unless otherwise noted.Remote Access (Total Connect) and Multi Mode (PSD) over IP or GSM cannot be enabled in the panel alone.Availability of this service is controlled via the web-based programming tool on the AlarmNet Direct website. Thesefeatures must to be enabled through the AlarmNet Direct website first and transferred to the device.SCREEN ACTION5000-100-132-V0CommunicatorCommunicator1. Select “Communicator”The System displays the following options:Communications Path Primary City IdPri Central Station Id Primary Subscriber IdSupervision Old Alarm TimeRemote Acc. IP or GSM Multi Mode IP or GSMUse the down T arrow to scroll to the next page of options.GSM Fault TimeORIP Fault TimeCommunications PathNone2. Select “Communications Path”. The system scrolls between the following options:NoneIPGSMPrimary City Id 3. Select “Primary City Id”. Enter the 2-digit Primary City ID (Decimal).Options01-99Pri Central Station Id 4. Select “Pri Central Station Id”. Enter the 2-digit Primary Central Station ID (HEX).Options01-FEPrimary Subscriber Id 5. Select “Primary Subscriber Id”. Enter the 4-digit Subscriber Account Number(Decimal).Options0001-9999WWW.DIYALARMFORUM.COM