55www.gateway.comBaseboard Management Controller (BMC)■ Update the non-volatile storage device associated with the BMC that holds the SDRand FRU information■ Generically handle FRU devices that might not be associated with the BMC■ View and direct results to the standard output deviceEach time you update the FRU/SDR, we recommend that you checksupport.gateway.com for the most current version of the utility. If you find a versionthat is newer than the one included on the SCCD, download the newer version anduse it instead of the SCCD, following the instructions included with the new files. Ifyou are using the SCCD to update the FRU/SDR, use the following procedure.To update the FRU/SDR:1 Download the current SUP CD image from www.support.gateway.com and create aDOS-bootable SUP CD. For information on creating a SUP CD, see “Creating aDOS-bootable System Update Package (SUP) CD” on page 42.2 Put the SUP CD in the CD drive and reboot from the CD.3 Open the FRU folder and click FRUSDR.EXE.4 When you are asked if you have an optional cooling kit installed, type Y if your systemhas redundant fans installed or N if your system has only the basic fans installed.5 Exit the utility, remove the CD, then reboot your server.The SEL Viewer utilityThe SEL Viewer is a utility that lets you view the SEL (System Event Log) records, save SELentries to a file, and load SEL entries from a file. You can also reload SEL entries from aserver, view the properties of SEL entries, clear SEL entries from non-volatile memory, andsort SEL records by various criteria. SEL entries can be viewed in either interpreted textmode or hex mode.Download the current SUP CD image from support.gateway.com for the most currentversion of the utility.To use the SEL viewer utility:1 Download the current SUP CD image from www.support.gateway.com and create aDOS-bootable SUP CD. For information on creating a SUP CD, see “Creating aDOS-bootable System Update Package (SUP) CD” on page 42.2 Put the SUP CD in the CD drive and reboot from the CD.