2-8 C70 Capacitor Bank Protection and Control System GE Multilin2.2 ORDER CODES 2 PRODUCT DESCRIPTION22.2ORDER CODES 2.2.1 OVERVIEWThe C70 is available as a 19-inch rack horizontal mount or reduced-size (¾) vertical unit and consists of the following mod-ules: power supply, CPU, CT/VT, digital input and output, transducer input and output, and inter-relay communications.Each of these modules can be supplied in a number of configurations specified at the time of ordering. The informationrequired to completely specify the relay is provided in the following tables (see chapter 3 for full details of relay modules).Order codes are subject to change without notice. See the ordering page athttp://www.gegridsolutions.com/multilin/order.htm for the latest options.The order code structure is dependent on the mounting option (horizontal or vertical) and the type of CT/VT modules(enhanced diagnostic CT/VT modules or HardFiber process bus modules). The order code options are described in the fol-lowing sub-sections.2.2.2 ORDER CODES WITH ENHANCED CT/VT MODULESThe order codes for the horizontal mount units are shown below.Table 2–4: C70 ORDER CODES (HORIZONTAL UNITS)C70 - * ** - * * * - F ** - H ** - M ** - P ** - U ** - W/X ** Full Size Horizontal MountBASE UNIT C70 | | | | | | | | | | | Base UnitCPU T | | | | | | | | | | RS485 with 3 100Base-FX Ethernet, multimode, SFP with LCU | | | | | | | | | | RS485 with 1 100Base-T Ethernet, SFP RJ-45 + 2 100Base-FX Ethernet, multimode, SFP with LCV | | | | | | | | | | RS485 with 3 100Base-T Ethernet, SFP with RJ-45SOFTWARE 00 | | | | | | | | | No software options03 | | | | | | | | | IEC 6185012 | | | | | | | | | Enhanced capacitor bank control (time and date, capacitor control supervision, automatic voltage regulator)13 | | | | | | | | | Enhanced capacitor bank control and IEC 61850A0 | | | | | | | | | CyberSentry Lvl 1A3 | | | | | | | | | CyberSentry Lvl 1 and IEC 61850AC | | | | | | | | | CyberSentry Lvl 1 and enhanced capacitor bank controlAD | | | | | | | | | CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank controlB0 | | | | | | | | | IEEE 1588B3 | | | | | | | | | IEEE 1588 and IEC 61850BC | | | | | | | | | IEEE 1588 and enhanced capacitor bank controlBD | | | | | | | | | IEEE 1588, IEC 61850, and enhanced capacitor bank controlC0 | | | | | | | | | Parallel Redundancy Protocol (PRP)C3 | | | | | | | | | PRP and IEC 61850CC | | | | | | | | | PRP and Enhanced Capacitor Bank ControlCD | | | | | | | | | PRP, IEC 61850, and Enhanced Capacitor Bank ControlD0 | | | | | | | | | IEEE 1588 and CyberSentry Lvl 1D3 | | | | | | | | | IEEE 1588, CyberSentry Lvl 1, and IEC 61850DC | | | | | | | | | IEEE 1588, CyberSentry Lvl 1, and enhanced capacitor bank controlDD | | | | | | | | | IEEE 1588, CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank controlE0 | | | | | | | | | IEEE 1588 and PRPE3 | | | | | | | | | IEEE 1588, PRP, and IEC 61850EC | | | | | | | | | IEEE 1588, PRP, enhanced capacitor bank controlED | | | | | | | | | IEEE 1588, PRP, IEC 61850, and enhanced capacitor bank controlF0 | | | | | | | | | PRP and CyberSentry Lvl 1F3 | | | | | | | | | PRP, CyberSentry Lvl 1, and IEC 61850FC | | | | | | | | | PRP, CyberSentry Lvl 1, and enhanced capacitor bank controlFD | | | | | | | | | PRP, CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank controlG0 | | | | | | | | | IEEE 1588, PRP, and CyberSentry Lvl 1G3 | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850GC | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, and enhanced capacitor bank controlGD | | | | | | | | | IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank controlJ0 | | | | | | | | | IEC 60870-5-103J3 | | | | | | | | | IEC 60870-5-103 and IEC 61850JC | | | | | | | | | IEC 60870-5-103 and enhanced capacitor bank controlJD | | | | | | | | | IEC 60870-5-103, IEC 61850, and enhanced capacitor bank controlK0 | | | | | | | | | IEEE 1588, PRP, and IEC 60870-5-103K3 | | | | | | | | | IEEE 1588, PRP, IEC 60870-5-103, and IEC 61850KC | | | | | | | | | IEEE 1588, PRP, IEC 60870-5-103, and enhanced capacitor bank controlKD | | | | | | | | | IEEE 1588, PRP, IEC 60870-5-103, IEC 61850, and enhanced capacitor bank controlL0 | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, and CyberSentry Lvl 1L3 | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, CyberSentry Lvl 1, and IEC 61850LC | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, CyberSentry Lvl 1, and enhanced capacitor bank controlLD | | | | | | | | | IEC 60870-5-103, IEEE 1588, PRP, CyberSentry Lvl 1, IEC 61850, and enhanced capacitor bank controlMOUNT/COATING H | | | | | | | | Horizontal (19” rack)A | | | | | | | | Horizontal (19” rack) with harsh-environment coatingFACEPLATE/ DISPLAY C | | | | | | | English displayP | | | | | | | English display with 4 small and 12 large programmable pushbuttonsD | | | | | | | French displayR | | | | | | | Russian displayA | | | | | | | Chinese displayK | | | | | | | Enhanced front panel with English displayM | | | | | | | Enhanced front panel with French displayQ | | | | | | | Enhanced front panel with Russian displayU | | | | | | | Enhanced front panel with Chinese displayL | | | | | | | Enhanced front panel with English display and user-programmable pushbuttonsN | | | | | | | Enhanced front panel with French display and user-programmable pushbuttonsT | | | | | | | Enhanced front panel with Russian display and user-programmable pushbuttonsV | | | | | | | Enhanced front panel with Chinese display and user-programmable pushbuttonsW | | | | | | | Enhanced front panel with Turkish displayY | | | | | | | Enhanced front panel with Turkish display and user-programmable pushbuttonsI | | | | | | | Enhanced front panel with German displayJ | | | | | | | Enhanced front panel with German display and user-programmable pushbuttonsNOTE