REMOTE CONTROL – CSCPIn addition to GPI activated controls, the Hydra2 product range supports several protocols to allow 3rd partyequipment to remotely control various features. CSCP (Calrec Serial Control Protocol) can be used to remotelyautomate various Summa features.CSCPCalrec Serial Control Protocol (CSCP) allows remote control, using third party equipment, of the following:• Fader positions (including VCA master faders)• Path cut/on status• PFL status• Routing to auxs and mains• Aux output levels• Main output Level• ‘Left to both’ and ‘right to both’ switchingCSCP can be enabled and disabled per fader:1. Press a fader’s ACCESS button.2. Tap the fader processing tab.3. Tap CSCP ENABLE in the window header to switch on or off.When a fader is under CSCP control, this can be overridden by touching and dragging the fader to the desired level.Setting Up CSCPTap SYSTEM SETTINGS in the top right of the screen and select CONTROL PROTOCOLS from the left hand menu.In this window you can configure each CSCP controller device that you wish to connect to your network. On the leftof the screen the LAN port IP address information is displayed (see “Configuring LAN Ports” on page 176 for moreinformation) so that you have it available for configuring your CSCP controller. On the right of the screen you can addyour CSCP interface, EDIT the settings, switch on the connection or DELETE the controller from the system. By default,the Assist CSCP interface will already be defined. Use CSCP version 21 unless you have been advised otherwise by aCalrec engineer.176 SUMMA Networked Audio Production System EXTERNAL INTERFACING