166 en | Card Reader Keypad Functions Access Easy ControllerVer 2.0.0 | 2006.07 Hardware Manual Bosch Security SystemsS-Series reader LED indicators*Slow flashing is at around 1 sec ON then 1 sec OFF interval; whereas normal flashing is at ½ secinterval.The LED besides being used to indicate an alarm condition in the zone is also used during theArming process.When you arm the Alarm Zone, the LED will flash for the duration as depicted in the Arm Delayfield of that particular Alarm Zone. We provide a few example below for further understand-ing.Configuration in the AEC.X Input Points #1, 2, 3, and 4 are grouped as Alarm Zone #1.X Arm Delay = 15 seconds.X Alarm Delay = 0 secondsX Reader #4 is the Arm/Disarm Reader for Alarm Zone #1.X Some cards are given the access rights to arm/disarm Alarm Zone #1. No PIN coderequired.Arming an Alarm ZoneExample 1 - All Input Points are in the Normal state.1. LED has a stable green light.2. Press 0 key and Present the arming card to Reader #4.S-Series reader Status LED(Tri-color)ArmedLEDAlarmLEDInternalBuzzerArmedThe zone is ArmedRED RED OFF OFFReady/DisarmedAll input points in the zoneare in normal state and readyto be armed.GREEN OFF OFF OFFNot Ready(before Armed)One or more input points isnot in the normal state andnot ready for arming.GREEN/RED FlashingREDFlashingOFF OFFArmed Partial (Some inputBypass)Zone failed to be armed dueto certain input point(s) arenot ready.AMBER/RED FlashingREDFlashingOFF OFFArmed Fail (All input Bypass)Zone failed to be armed dueto all inputs are not ready.RED RED Flashing OFF OFFAlarmZone is armed and one ormore input point is in alarmstate.RED RED Flashing REDFlashing(slow*)BeepingON/OFFat 1 Secinterval