Access Easy Controller Secure/Communication Card | en 119Bosch Security Systems Hardware Manual Ver 2.0.0 | 2006.07However, if you are having the CE Listed version of Access Easy Controller, you could usesoutput provided by the 15V DC Input Power Supply Card to provide the triggering as shownon the following page.Internal wiring diagram between Power Supply board (CE Listed System) and Secure ComCardCN2 CN1BPIN 1PIN 1(P/N: AEC MOD COM)SECURE COMM. CARD4 3 2 11 2 3 4 21INT1 T2 T3(P/N: AEC MOD UPS1)15VDC INPUT POWER SUPPLY BOARD4 3 2 134 2 12 1 6 5