AUTODOME 7100i Configuration | en 53Bosch Security Systems B.V. User Manual 2022-12 | V01 | DOC– MonochromeThis switches the camera to the monochrome mode.– Switch modeWhen this is selected, you can select the Scene Mode to be used for the active andinactive period of the alarm.4.6.7 Alarm OutputsIdle stateSelect Open for the output to operate as a normally open contact, or select Closed if theoutput is to operate as a normally closed contact.Operating modeSelect an operating mode for the relay.For example, if you want an alarm-activated lamp to stay on after the alarm ends, selectBistable. If you wish an alarm-activated siren to sound for ten seconds, for example, select10 s.Output nameEnter a name for the alarm output.This name appears on the Live page.Note: This name appears in the Digital I/O section of the Live page.ToggleClick the button to test the relay / output connection.4.6.8 Alarm Task EditorEditing scripts on this page overwrites all settings and entries on the other alarm pages. Thisprocedure cannot be reversed.To edit this page, you should have programming knowledge and be familiar with theinformation in the Alarm Task Script Language document and the English language.As an alternative to the alarm settings on the various alarm pages, enter the desired alarmfunctions in script form here. This will overwrite all settings and entries on the other alarmpages.1. Click Examples under the Alarm Task Editor field to see some script examples. A newwindow opens.2. Enter new scripts in the Alarm Task Editor field or change existing scripts in line with yourrequirements.3. When finished, click Set to transmit the scripts to the device. If the transfer wassuccessful, the message Script successfully parsed. is displayed over the text field. If itwas not successful, an error message is displayed with further information.4.6.9 Alarm RulesAn alarm rule can define which input(s) activate which output(s). Basically, an alarm ruleallows you to configure the device to respond automatically to different alarm inputs.To configure an alarm rule, specify one input from a physical connection, from a motiondetection trigger, or from a connection to the device's LIVE page. The physical inputconnection can be activated by dry contact devices such as pressure pads, door contacts, andsimilar devices.Next, specify up to two (2) rule outputs, or the device's response to the input. Outputsinclude a physical alarm output, an AUX command, or a preposition scene.Select the required Input (a physical alarm connection) from the dropdown list: