Installation ManualH3C S7500 Series Ethernet Switches Chapter 7 Software Maintenance7-8Checking flash......done!SRPG bootrom update menu:1. Set TFTP protocol parameter2. Set FTP protocol parameter3. Set XMODEM protocol parameter0. Return to boot menuEnter your choice(0-3):311) Type 0 and press Enter to return to the Boot Menu. Then type 0 to reboot thesystem and the terminal displays the following information:Rebooting...Please change the terminal's baudrate to 9600 bps!12) Change the baud rate of the HyperTerminal back to 9600 bps as described inSteps 5 and 6. Then press any key as prompted.Note:You do not need to reset the HyperTerminal’s baud rate and can skip the last step if youhave chosen the baud rate 9600 bps. In this case, the terminal does not display themessage “Please change the terminal's baudrate to 9600 bps!” as shown in Step 11.III. Loading host softwareFollow these steps to download the host software of the switch:1) Select 1 from the Boot Menu. The terminal displays the following information:1. Set TFTP protocol parameter2. Set FTP protocol parameter3. Set XMODEM protocol parameter0. Return to boot menuEnter your choice(0-3):3You can select different protocols to load the host software.The subsequent steps are the same as those for updating the Boot ROM, except for theprompt information.7.2.3 Loading Software from the Management Ethernet Port Using TFTPI. Introduction to TFTPTrivial File Transfer Protocol (TFTP) is a TCP/IP protocol used for file transmissionbetween clients and servers. TFTP provides unreliable data transfer over UDP.