Installation ManualH3C S7500 Series Ethernet Switches Chapter 1 Product Overview1-6(1) (2) (3) (5) (6) (7) (8) (9)(14) (12)(4) (10)(13)(15)(11)(16)(17)(18)(19)(20)(21)(22)(1) SFP port number (2) SFP port (Gigabit)(3) Console port (4) Management Ethernet port(5) LINK LED of the management Ethernetport(6) ACT LED of the management Ethernetport(7) RUN LED of LPU (8) ALM LED of LPU(9) RUN LED of SRPU (10) ALM LED of SRPU(11) Silkscreen (12) Captive screw(13) SRPU edge (pink) (14) RESET button(15) Ejector lever (16) OK LED of the power(17) FAIL LED of the power (18) OK LED of the fan(19) FAIL LED of the fan (20) SFP port status LED(21) CF card port (22) Button for ejecting the CF cardFigure 1-5 Panel of a Salience III Series SRPU (LS81SRPG)Note:z The panel of a Salience III Edge SRPU is the same as that of a Salience III SRPUexcept the board name and board silk-screen.z The panel of a Salience III Plus SRPU is the same as that of a Salience III SRPUexcept that it has a different board name and board silk-screen and provides no SFPport.1.3.4 PortsI. CF card portThe port supports standard CF cards. The CF card stores the host version to facilitatethe online software upgrade.