Easy Message (828D only)16.4 Setting-up eventsMillingOperating Manual, 03/2010, 6FC5398-7CP20-1BA0 547● Measuring cycle messages for toolsAn SMS is sent if measuring cycle messages are output that involve tools.● Measuring cycle messages for workpiecesAn SMS is sent if measuring cycle messages are output that involve workpieces.● Sinumerik messages/alarms (error when executing)An SMS is sent if NCK alarms or messages are output that cause the machine to come toa standstill.● Machine faultsAn SMS is sent if PLC alarms or messages are output that cause the machine to come toa standstill (i.e. PLC alarms with Emergency Off response).● Maintenance intervalsAn SMS is sent if the service planner registers pending maintenance work.● Additional alarm numbers:Here, specify additional alarms where you should be notified if they occur.You can enter individual alarms, several alarms or alarm number ranges.Examples:1234,4001000-2000100,200-300Requirement● The user profile window is opened.● You selected the event "Measuring cycle messages for tools", "Measuring cyclemessages for workpieces", "Sinumerik messages/alarms (errors when executing)","Machine faults" or "Maintenance intervals".Editing events1. Activate the required check box and press the "Details" softkey.The appropriate window opens (e.g. "Measuring cycle messages forworkpieces") and shows a list of the defined alarm numbers.2. Select the corresponding entry and press the "Delete" softkey toremove the alarm number from the list.- OR -Then press the "New" softkey if you wish to create a new entry.The "Create new entry" window opens.Enter the data and press the "OK" softkey to add the entry to the list.